ACT OF 1990 BETWEEN THE UNITED STATES OF AMERICA AND
THE ORLANDO SCIENCE CENTER
DJ# 202-17M-81
1) The Center agrees to remove 3 seats from the center of the front row of Theater 2051 to create 2 more wheelchair spaces, making a total of 4 wheelchair spaces with fixed companion seating located next to each of them.
2) The Center agrees to remove 3 seats from the last row of the Planetarium to create 2 more wheelchair locations, making a total of 6 wheelchair spaces with fixed companion seating located next to each of them.
3) The Center agrees to reverse the doors to Men's Room 3038 and Women's Room 3037 so that they swing into the corridor. The Center will ensure that all of the toilet room fixtures in rooms 3038 and 3037 are accessible and will provide grab bars at the toilet.
1) The Center agrees to lower counter tops at sinks by 2 inches in Storage Rooms 2020 and 2026 so that the entire counter in each room will be 34 inches above the floor. The Center will ensure that the pipes under the accessible sinks are insulated or otherwise configured to protect against contact.
2) The Center agrees to remove the sinks located in the accessible toilet stalls of Men's Room 1041 and Women's Room 1044 and relocate them to an area outside of the stalls. The Center will ensure that the accessible lavatories will fully comply with § 4.19 of the Standards.
3) The Center agrees to remove a non-complying urinal in Men's Room 1098 and replace it with an accessible urinal that complies fully with § 4.18 of the Standards.
1) The Center agrees to renovate Food Service Staff Men's Room 1082 and Women's Room 1083 to provide, in each room, grab bars, a shower seat, and a shower spray unit with a hose at least 60 inches long that it can be used both as a fixed shower head and as a hand-held shower. The Center will ensure that each shower head is located opposite the shower seat per Figure 37 of the Standards.
2) The Center agrees to lower counter tops at sinks by 2 inches in Employee Break Room 1073 and Volunteer Lounge 1102 so that the entire counter in each room will be 34 inches above the floor. The Center will ensure that the pipes under the accessible sinks are insulated or otherwise configured to protect against contact.
3) The Center agrees to modify the door of Theater Toilet Room 1018 so that it opens outward, to make the sink and toilet accessible, and to add grab bars. It is understood that, due to structural limitations, the agreed upon modifications are the most that can be done to make room 1018 accessible.
4) The Center agrees to lower counter tops at sinks by 2 inches in Galley Rooms 3025 and 3045 so that the entire counter in each room will be 34 inches above the floor. The Center will ensure that the pipes under the accessible sinks are insulated or otherwise configured to protect against contact.
1) The Center agrees to add a 3 foot wide swinging door, frame and light lock hardware to Photo Lab 1074. The Center will place a warning sign on the door noting that the door services a photo lab and processing of film may be in progress.
The Center will ensure that the pull-side maneuvering clearance of the new door is at least 18 inches wide past the latch-side of the door for 60 inches deep, so the existing light-lock rotating door is not within the maneuvering clearance.
1) The Center agrees to place a new door in each of the lobbies to Men's Rooms 2065, 3065, and 4043 and Women's Rooms 2064, 3064, and 4042 and to make the necessary modifications so that the accessible toilets located in adjacent rooms will be located within the previously mentioned rooms to serve as the accessible stall in each of these rooms; to provide accessible urinals in rooms 2065, 3065, and 4043, that are in full compliance with the Standards; and to provide an accessible sink in each of the previously mentioned rooms that is in full compliance with the Standards. The Center agrees that the sinks located in the previously mentioned adjacent rooms will be removed to provide adequate transfer/clear floor space for the accessible stalls to be located in rooms 2065, 2064, 3065, 3064, 4043 and 4042, per Figure 30(a) of the Standards.
The Center will ensure that, in each of these rooms, the vestibule between each of the toilet room entry doors and the doors to the accessible stalls will be the door width plus 48 inches deep.
2) The Center agrees to substantially modify Toilet Room 2030 to allow an accessible toilet stall to be located in Men's Room 2029 and Women's Room 2031 and to remove the sink in the accessible stall of the modified Women's Room 2031 to provide the required transfer/clear floor space for the toilet per Figure 30 of the Standards.
The Center will ensure that the accessible urinal in Men's Room 2029 is in full compliance with the Standards; that the toilet partition door in Men's Room 2029 cannot swing into the clear floor space of the accessible urinal; and that an accessible lavatory and mirror will be placed in Women's Room 2031.
For the United States:
Bill Lann Lee
Assistant Attorney General
By:_____________________________  :  : Date: _________________
John L. Wodatch, Chief
Renee M. Wohlenhaus, Deputy Chief
Susan B. Reilly, Supervisory Attorney
Charles Harvey, Investigator
Disability Rights Section
Civil Rights Division
U.S. Department of Justice
P.O. Box 66738
Washington, D.C. 20035-6738
Orlando Science Center
By: ____________________________  :  : Date: ___________________
 :  : Orlando Science Center
 :  : 777 East Princeton Street
 :  : Orlando, Florida 32803